High-Void Underground Soakaway & Drainage Crates

High-void underground soakaway crates create usable stormwater storage with less excavation than solid or low-porosity fill. Within the GS Tank range, listed void ratios are approximately 88–95%, depending on the module. This allows most of the installed gross tank volume to hold water while the internal columns and plates provide the structural load path.

Void ratio is important, but it is only one selection factor. Infiltration performance depends mainly on the receiving soil, wetted area, groundwater separation and pretreatment. Structural performance depends on the exact crate, material grade, assembly, cover and surface load.

What does void ratio mean?

Void ratio is the proportion of a module’s external volume that can be occupied by water. For preliminary sizing:

Nominal active volume = installed gross module volume × verified void ratio

The final usable volume may be lower after accounting for pipe inverts, freeboard, sediment allowance, permanent water level and any inaccessible portion of the tank. Use the manufacturer’s current calculation method and the engineer’s hydraulic model for final sizing.

High-void soakaway crate comparison

ModelNominal sizeListed void ratioListed water volumeIndicative load rangeUnit weight
M2014680 × 410 × 450 mm88–92%110 L25–35 t/m²8 kg
M2015H800 × 490 × 250 mm88–92%90 L28–38 t/m²7.5 kg
M2015F800 × 490 × 530 mm90–93%185 L28–38 t/m²12.7 kg
M2016S1,000 × 500 × 500 mm90–93%235 L30–40 t/m²15 kg
M2016B1,200 × 600 × 700 mm90–95%475 L35–45 t/m²27 kg

Figures shown are historical listing data for initial comparison. Before design or procurement, request the current drawing, verified void ratio, PP grade, test report and allowable design values for the proposed configuration.

M2014

M2014 high-void underground drainage crate

M2015H

M2015H shallow high-void soakaway module

M2015F

M2015F high-void rainwater storage crate

M2016S

M2016S high-void infiltration tank module

M2016B

M2016B high-volume underground soakaway crate

High void ratio does not equal high infiltration rate

The crates provide temporary storage and an open path for water within the tank. The rate at which water leaves an infiltration system is controlled by soil permeability, the effective infiltration area, groundwater and clogging risk. A larger void ratio increases storage efficiency, but it cannot compensate for unsuitable ground.

  • Complete infiltration testing at the proposed depth.
  • Confirm seasonal groundwater and required separation.
  • Check setbacks from foundations, boundaries, wells and contaminated land.
  • Provide pretreatment to limit sediment entering the geotextile and surrounding soil.
  • Model drawdown time and an emergency overflow route.

High-void soakaway crate system below ground

Balance storage efficiency and structural design

An underground tank must resist vertical and lateral loads throughout construction and service. Selection should use an allowable project design value, not only a short-term maximum test result. The engineer should review material grade, creep, temperature, cover depth, backfill, pavement structure, traffic, groundwater uplift and installation tolerances.

Higher void ratio is beneficial only when the internal structure and complete installation still meet the required safety factors. Ask for model-specific reports and confirm whether the tested product matches the proposed recycled or virgin PP option.

Interconnected high-void stormwater drainage crates

Pretreatment protects the available void space

Silt accumulation reduces hydraulic performance and may be difficult to remove from a buried cell structure. The drainage design should keep sediment out of the tank rather than relying on the modules to “self-clean.”

  • Use leaf screens and filtration for roof-water systems.
  • Use accessible catch pits, silt traps and appropriate pollution control for surface runoff.
  • Locate inspection and maintenance points before the tank inlet.
  • Prevent construction debris from entering during installation.
  • Define an inspection and cleaning schedule for upstream components.

Plastic high-void soakaway crate components

Underground drainage crate system components

Module structure

M2015 series: a plate-based assembly that can form different depths in accordance with the model drawing. Structural plates and connectors must be installed in the specified positions.

M2015 high-void drainage crate plate assembly

M2016 series: a column-and-plate format providing larger individual module volume for suitable tank footprints.

M2016 high-void soakaway crate column structure

Typical applications

  • Soakaways serving roofs, courtyards and suitable paved catchments
  • Stormwater attenuation below landscaping or parking areas
  • Lined rainwater harvesting tanks for irrigation or approved reuse
  • Drainage storage alongside roads and public-realm projects
  • Commercial, residential and municipal water-management systems

Frequently asked questions

Is a 95% void ratio always better than 90%?

Not automatically. The required depth, footprint, load capacity, assembly time, material and supporting test evidence may be more important for a particular project.

Can listed water volume be used directly for final sizing?

Use it for early comparison only. Final active volume must follow the approved tank geometry and account for hydraulic levels, freeboard, sediment allowance and verified void ratio.

Do high-void crates require maintenance?

The buried cells are normally protected from direct access, so upstream pretreatment and inspection components must be maintainable. “No maintenance” should not be assumed for the complete drainage system.

Compare models and request current data

Review the underground rainwater tank systems and model pages for M2014, M2015H, M2015F, M2016S and M2016B.

Installed high-void underground soakaway crate tank

Send the tank volume, dimensions, rainfall, soil, groundwater, cover and loading requirements for current technical data and quotation.

Get in Touch

We'd love to hear from you. Please fill out the form below.

Please enable JavaScript in your browser to complete this form.